Central corneal thickness and tonometric intraocular pressure in healthy young Malaysian Chinese adults
Medical hypothesis, discovery & innovation in optometry,
Vol. 7 No. 3 (2026),
31 October 2026
,
Page 154-163
https://doi.org/10.51329/mehdioptometry256
Abstract
Background: Central corneal thickness (CCT) can influence intraocular pressure (IOP) readings, but the relationship varies across tonometers and populations. This study examined the associations between CCT and uncorrected IOP measured using Canon TX-F non-contact tonometry (NCT) and AccuPen contact applanation tonometry in healthy young Malaysian Chinese adults.Methods: This cross-sectional comparative study was conducted at UCSI University, Kuala Lumpur, Malaysia, between July and October 2019. Participants aged 18–25 years were recruited through voluntary, non-probability sampling. Eligibility required best-corrected visual acuity of 6/6 or better in each eye and clinically healthy anterior segments and optic nerve heads. A single optometrist performed bilateral examinations between 12:00 and 17:00 in a fixed sequence: NCT, ultrasonic pachymetry using AccuPach VI, and AccuPen tonometry. Three valid measurements per eye were averaged for each instrument. IOP readings were analysed without CCT correction.
Results: Of 98 individuals screened, 84 were enrolled, including 30 (35.7%) men and 54 (64.3%) women. Mean (standard deviation [SD]) age was 21.61 (1.88) years, and mean (SD) CCT was 570.11 (36.50) µm. Mean (SD) IOP was 15.50 (2.13) mmHg with NCT and 13.00 (2.35) mmHg with AccuPen. NCT readings were higher by a mean paired difference of 2.50 mmHg (95% confidence interval [CI], 2.11–2.89; P < 0.001). CCT was positively correlated with NCT readings (r = 0.339; 95% CI, 0.134–0.516; P < 0.05) and AccuPen readings (r = 0.310; 95% CI, 0.103–0.491; P < 0.05). CCT accounted for 11.5% and 9.6% of the variance in NCT and AccuPen readings, respectively. The regression slopes were numerically similar, corresponding to approximately 0.20 mmHg higher measured IOP per 10-µm greater CCT.
Conclusions: Greater CCT was associated with higher uncorrected IOP readings from both tonometers, while NCT yielded higher mean readings. These findings support considering CCT and instrument type when interpreting IOP in this population, without establishing device interchangeability or equivalent CCT sensitivity. Future studies in larger, more representative samples should examine how closely IOP readings from Canon TX-F NCT and AccuPen agree and how consistent repeated measurements are with each device.
- corneal pachymetry
- intraocular pressure
- tonometry
- ocular
- young adult
- cross-sectional studies
References
Brusini P, Salvetat ML, Zeppieri M. How to Measure Intraocular Pressure: An Updated Review of Various Tonometers. J Clin Med. 2021 Aug 27;10(17):3860. doi: 10.3390/jcm10173860. PMID: 34501306; PMCID: PMC8456330.
Belovay GW, Goldberg I. The thick and thin of the central corneal thickness in glaucoma. Eye (Lond). 2018 May;32(5):915-923. doi: 10.1038/s41433-018-0033-3. Epub 2018 Feb 15. PMID: 29445115; PMCID: PMC5944650.
Gordon MO, Beiser JA, Brandt JD, Heuer DK, Higginbotham EJ, Johnson CA, Keltner JL, Miller JP, Parrish RK 2nd, Wilson MR, Kass MA. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol. 2002 Jun;120(6):714-20; discussion 829-30. doi: 10.1001/archopht.120.6.714. PMID: 12049575.
Tonnu PA, Ho T, Newson T, El Sheikh A, Sharma K, White E, Bunce C, Garway-Heath D. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol. 2005 Jul;89(7):851-4. doi: 10.1136/bjo.2004.056622. PMID: 15965165; PMCID: PMC1772720.
García-Resúa C, Giráldez Fernández MJ, Yebra-Pimentel E, García-Montero S. Clinical evaluation of the Canon TX-10 noncontact tonometer in healthy eyes. Eur J Ophthalmol. 2010 May-Jun;20(3):523-30. doi: 10.1177/112067211002000326. PMID: 20037897.
Cook JA, Botello AP, Elders A, Fathi Ali A, Azuara-Blanco A, Fraser C, McCormack K, Margaret Burr J; Surveillance of Ocular Hypertension Study Group. Systematic review of the agreement of tonometers with Goldmann applanation tonometry. Ophthalmology. 2012 Aug;119(8):1552-7. doi: 10.1016/j.ophtha.2012.02.030. Epub 2012 May 10. PMID: 22578443.
Chua J, Tham YC, Liao J, Zheng Y, Aung T, Wong TY, Cheng CY. Ethnic differences of intraocular pressure and central corneal thickness: the Singapore Epidemiology of Eye Diseases study. Ophthalmology. 2014 Oct;121(10):2013-22. doi: 10.1016/j.ophtha.2014.04.041. Epub 2014 Jun 18. PMID: 24950592.
Ma D, Wei S, Sun Y, Li SM, An WZ, Hu JP, Cao K, Yang XH, Lin CX, Guo JY, Li H, Fu J, Wang N. Distribution of IOP and its relationship with refractive error and other factors: the Anyang University Students Eye Study. Int J Ophthalmol. 2021 Apr 18;14(4):554-559. doi: 10.18240/ijo.2021.04.12. PMID: 33875947; PMCID: PMC8025177.
Tzamalis A, Tsiampali C, Prousali E, Mataftsi A, Ziakas N, Kynigopoulos M. Reliability of Refraction, Keratometry, and Intraocular Pressure Measurements with an Automated All-in-one Device. Optom Vis Sci. 2021 Oct 1;98(10):1169-1176. doi: 10.1097/OPX.0000000000001781. PMID: 34620780.
Hao J, Zhen Y, Wang H, Yang D, Wang N. The effect of lateral decubitus position on nocturnal intraocular pressure over a habitual 24-hour period in healthy adults. PLoS One. 2014 Nov 25;9(11):e113590. doi: 10.1371/journal.pone.0113590. PMID: 25423190; PMCID: PMC4244118.
Faul F, Erdfelder E, Buchner A, Lang AG. Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses. Behav Res Methods. 2009 Nov;41(4):1149-60. doi: 10.3758/BRM.41.4.1149. PMID: 19897823.
Cohen J. A power primer. Psychol Bull. 1992 Jul;112(1):155-9. doi: 10.1037//0033-2909.112.1.155. PMID: 19565683.
Kaur K, Gurnani B. Subjective Refraction Techniques. 2023 Jun 11. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2023 Jan–. PMID: 35593807.
Aluyi-Osa G, Musa MJ, Zeppieri M. Jackson Cross Cylinder. 2023 May 22. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2023 Jan–. PMID: 36508527.
Musa MJ, Zeppieri M. Principles and Technique of Fogging During Refraction. 2026 Aug 17. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2026 Jan–. PMID: 36251830.
Venkataraman AP, Sirak D, Brautaset R, Dominguez-Vicent A. Evaluation of the Performance of Algorithm-Based Methods for Subjective Refraction. J Clin Med. 2020 Sep 29;9(10):3144. doi: 10.3390/jcm9103144. PMID: 33003297; PMCID: PMC7599794.
Gandhi M, Dubey S. Evaluation of the Optic Nerve Head in Glaucoma. J Curr Glaucoma Pract. 2013 Sep-Dec;7(3):106-14. doi: 10.5005/jp-journals-10008-1146. Epub 2013 Sep 6. PMID: 26997792; PMCID: PMC4741153.
Ansari-Shahrezaei S, Maar N, Biowski R, Stur M. Biomicroscopic measurement of the optic disc with a high-power positive lens. Invest Ophthalmol Vis Sci. 2001 Jan;42(1):153-7. PMID: 11133860.
Bourne RR. The optic nerve head in glaucoma. Community Eye Health. 2012;25(79-80):55-7. PMID: 23520418; PMCID: PMC3588134.
Budenz DL, Anderson DR, Feuer WJ, Beiser JA, Schiffman J, Parrish RK 2nd, Piltz-Seymour JR, Gordon MO, Kass MA; Ocular Hypertension Treatment Study Group. Detection and prognostic significance of optic disc hemorrhages during the Ocular Hypertension Treatment Study. Ophthalmology. 2006 Dec;113(12):2137-43. doi: 10.1016/j.ophtha.2006.06.022. Epub 2006 Sep 25. PMID: 16996592; PMCID: PMC1995568.
Read SA, Collins MJ, Iskander DR. Diurnal variation of axial length, intraocular pressure, and anterior eye biometrics. Invest Ophthalmol Vis Sci. 2008 Jul;49(7):2911-8. doi: 10.1167/iovs.08-1833. Epub 2008 Mar 24. PMID: 18362106.
Chakraborty R, Read SA, Collins MJ. Diurnal variations in axial length, choroidal thickness, intraocular pressure, and ocular biometrics. Invest Ophthalmol Vis Sci. 2011 Jul 11;52(8):5121-9. doi: 10.1167/iovs.11-7364. PMID: 21571673.
Mohan S, Tiwari S, Jain A, Gupta J, Sachan SK. Clinical comparison of Pulsair non-contact tonometer and Goldmann applanation tonometer in Indian population. J Optom. 2014 Apr-Jun;7(2):86-90. doi: 10.1016/j.optom.2013.06.002. Epub 2013 Jul 26. PMID: 24766865; PMCID: PMC4009465.
Kim JS, Rho CR, Cho YW, Shin J. Comparison of corneal thickness measurements using ultrasound pachymetry, noncontact tonopachy, Pentacam HR, and Fourier-domain OCT. Medicine (Baltimore). 2021 Apr 23;100(16):e25638. doi: 10.1097/MD.0000000000025638. PMID: 33879743; PMCID: PMC8078248.
Xie Y, Yang Y, Han Y, Yang D, Sun Y, Wang X, Nguyen AH, Chen Y, Tian J, Zhang Q, Xin C, Cao K, Wang H, Liu X, Wang G, Wang N. Association Between Arterial Blood Gas Variation and Intraocular Pressure in Healthy Subjects Exposed to Acute Short-Term Hypobaric Hypoxia. Transl Vis Sci Technol. 2019 Nov 20;8(6):22. doi: 10.1167/tvst.8.6.22. PMID: 31788351; PMCID: PMC6871546.
Armstrong RA. Statistical guidelines for the analysis of data obtained from one or both eyes. Ophthalmic Physiol Opt. 2013 Jan;33(1):7-14. doi: 10.1111/opo.12009. PMID: 23252852.
Li P, Hu Y, Xu Q, Zhang G, Mai C. Central corneal thickness in adult Chinese. J Huazhong Univ Sci Technolog Med Sci. 2006;26(1):141-4. doi: 10.1007/BF02828062. PMID: 16711030.
Sun Y, Wei S, Li S, Cao K, Hu J, Yang X, Lin C, An W, Guo J, Li H, Fu J, Wang N. Distribution of ocular biometry in young Chinese eyes: The Anyang University Students Eye Study. Acta Ophthalmol. 2021 Sep;99(6):621-627. doi: 10.1111/aos.14710. Epub 2020 Dec 16. PMID: 33326192.
Fern KD, Manny RE, Gwiazda J, Hyman L, Weise K, Marsh-Tootle W; COMET Study Group. Intraocular pressure and central corneal thickness in the COMET cohort. Optom Vis Sci. 2012 Aug;89(8):1225-34. doi: 10.1097/OPX.0b013e3182639fc7. PMID: 22820476; PMCID: PMC3726188.
Ma R, Liu Y, Zhang L, Lei Y, Hou J, Shen Z, Yi X, Wang Y. Distribution and Trends in Corneal Thickness Parameters in a Large Population-Based Multicenter Study of Young Chinese Adults. Invest Ophthalmol Vis Sci. 2018 Jul 2;59(8):3366-3374. doi: 10.1167/iovs.18-24332. PMID: 30025097.
Aghaian E, Choe JE, Lin S, Stamper RL. Central corneal thickness of Caucasians, Chinese, Hispanics, Filipinos, African Americans, and Japanese in a glaucoma clinic. Ophthalmology. 2004 Dec;111(12):2211-9. doi: 10.1016/j.ophtha.2004.06.013. PMID: 15582076.
Badr M, Masis Solano M, Amoozgar B, Nguyen A, Porco T, Lin S. Central Corneal Thickness Variances Among Different Asian Ethnicities in Glaucoma and Nonglaucoma Patients. J Glaucoma. 2019 Mar;28(3):223-230. doi: 10.1097/IJG.0000000000001180. PMID: 30624387.
Kan E, Duran M, Yakar K. Comparison of central corneal thickness measurements using three different imaging devices. J Fr Ophtalmol. 2023 Jun;46(6):589-595. doi: 10.1016/j.jfo.2022.09.029. Epub 2023 Apr 17. PMID: 37076388.
Wong AC, Wong CC, Yuen NS, Hui SP. Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry. Eye (Lond). 2002 Nov;16(6):715-21. doi: 10.1038/sj.eye.6700211. PMID: 12439665.
Scotto R, Bagnis A, Papadia M, Cutolo CA, Risso D, Traverso CE. Comparison of Central Corneal Thickness Measurements Using Ultrasonic Pachymetry, Anterior Segment OCT and Noncontact Specular Microscopy. J Glaucoma. 2017 Oct;26(10):860-865. doi: 10.1097/IJG.0000000000000745. PMID: 28834824.
Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000 Mar-Apr;44(5):367-408. doi: 10.1016/s0039-6257(00)00110-7. PMID: 10734239.
Pelit A, Altan-Yaycioglu R, Pelit A, Akova YA. Effect of corneal thickness on intraocular pressure measurements with the Pascal dynamic contour, Canon TX-10 non-contact and Goldmann applanation tonometers in healthy subjects. Clin Exp Optom. 2009 Jan;92(1):14-8. doi: 10.1111/j.1444-0938.2008.00299.x. Epub 2008 Jul 10. PMID: 18637107.
Bhan A, Browning AC, Shah S, Hamilton R, Dave D, Dua HS. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Invest Ophthalmol Vis Sci. 2002 May;43(5):1389-92. PMID: 11980851.
Bao B, Diaconita V, Schulz DC, Hutnik C. Tono-Pen versus Goldmann Applanation Tonometry: A Comparison of 898 Eyes. Ophthalmol Glaucoma. 2019 Nov-Dec;2(6):435-439. doi: 10.1016/j.ogla.2019.07.004. Epub 2019 Jul 27. PMID: 32672578.
Yildirim N, Sahin A, Basmak H, Bal C. Effect of central corneal thickness and radius of the corneal curvature on intraocular pressure measured with the Tono-Pen and noncontact tonometer in healthy schoolchildren. J Pediatr Ophthalmol Strabismus. 2007 Jul-Aug;44(4):216-22. doi: 10.3928/01913913-20070701-02. PMID: 17694826.
Bewick V, Cheek L, Ball J. Statistics review 7: Correlation and regression. Crit Care. 2003 Dec;7(6):451-9. doi: 10.1186/cc2401. Epub 2003 Nov 5. PMID: 14624685; PMCID: PMC374386.
Bunce C, Patel KV, Xing W, Freemantle N, Doré CJ; Ophthalmic Statistics Group. Ophthalmic statistics note 2: absence of evidence is not evidence of absence. Br J Ophthalmol. 2014 May;98(5):703-5. doi: 10.1136/bjophthalmol-2013-304811. Epub 2014 Mar 3. PMID: 24590556; PMCID: PMC3995227.
Broman AT, Congdon NG, Bandeen-Roche K, Quigley HA. Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure. J Glaucoma. 2007 Oct-Nov;16(7):581-8. doi: 10.1097/IJG.0b013e3180640f40. PMID: 18091174.
Tranchina L, Lombardo M, Oddone F, Serrao S, Schiano Lomoriello D, Ducoli P. Influence of corneal biomechanical properties on intraocular pressure differences between an air-puff tonometer and the Goldmann applanation tonometer. J Glaucoma. 2013 Jun-Jul;22(5):416-21. doi: 10.1097/IJG.0b013e31824cafc9. PMID: 22366703.
Dey A, David RL, Asokan R, George R. Can Corneal Biomechanical Properties Explain Difference in Tonometric Measurement in Normal Eyes? Optom Vis Sci. 2018 Feb;95(2):120-128. doi: 10.1097/OPX.0000000000001175. PMID: 29370019.
Gan W, Zhang Y, Yang S, He P, Hu Q, Du Z. The influence of ocular parameters on intraocular pressure values measured by different devices and the development of an optimized prediction model in a myopic population. Adv Ophthalmol Pract Res. 2025 Dec 17;6(1):87-94. doi: 10.1016/j.aopr.2025.12.003. PMID: 41704569; PMCID: PMC12907073.
Yilmaz I, Altan C, Aygit ED, Alagoz C, Baz O, Ahmet S, Urvasizoglu S, Yasa D, Demirok A. Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL. Clin Ophthalmol. 2014 Jun 7;8:1069-74. doi: 10.2147/OPTH.S63915. PMID: 24944507; PMCID: PMC4057323.
Osman EA, Gikandi PW, Al-Jasser AA, Alotaibi M, Mousa A. Comparison of Goldmann Applanation, Noncontact Air Puff, and Tono-Pen XL Tonometry in Normal Controls versus Glaucoma Patients at a University Hospital in Riyadh, Saudi Arabia. Middle East Afr J Ophthalmol. 2018 Jan-Mar;25(1):8-13. doi: 10.4103/meajo.MEAJO_291_16. PMID: 29899644; PMCID: PMC5974822.
Yildiz A, Yasar T. Comparison of Goldmann applanation, non-contact, dynamic contour and tonopen tonometry measurements in healthy and glaucomatous eyes, and effect of central corneal thickness on the measurement results. Med Glas (Zenica). 2018 Aug 1;15(2):152-157. doi: 10.17392/960-18. PMID: 30047543.
Bang SP, Lee CE, Kim YC. Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous subjects. BMC Ophthalmol. 2017 Nov 2;17(1):199. doi: 10.1186/s12886-017-0593-1. PMID: 29096616; PMCID: PMC5668971.
Gui H, Zhang Y, Chang RT, Wang SY. Real-world agreement of same-visit Tono-Pen vs Goldmann applanation intraocular pressure measurements using electronic health records. Heliyon. 2023 Jul 27;9(8):e18703. doi: 10.1016/j.heliyon.2023.e18703. PMID: 37576221; PMCID: PMC10412763.
Fam HB, How AC, Baskaran M, Lim KL, Chan YH, Aung T. Central corneal thickness and its relationship to myopia in Chinese adults. Br J Ophthalmol. 2006 Dec;90(12):1451-3. doi: 10.1136/bjo.2006.101170. Epub 2006 Aug 17. PMID: 16916878; PMCID: PMC1857527.
Wu S, Zhang Z, Wang J, Gong X, Guo D, Ye N. Central corneal thickness, corneal endothelial cell density, and morphology in myopic eyes of young Chinese candidates for refractive surgery. Front Ophthalmol (Lausanne). 2026 Mar 6;6:1769734. doi: 10.3389/fopht.2026.1769734. PMID: 41867319; PMCID: PMC13002416.
Ma Y, Ma Y, Feng C, Shen M, Yuan Y. Ocular biometric parameters are associated with non-contact tonometry measured intraocular pressure in non-pathologic myopic patients. Int Ophthalmol. 2020 Feb;40(2):431-437. doi: 10.1007/s10792-019-01203-8. Epub 2019 Dec 2. PMID: 31792850.
Wang P, Song Y, Lin F, Wang Z, Gao X, Cheng W, Chen M, Peng Y, Liu Y, Zhang X, Chen S. Comparison of Non-contact Tonometry and Goldmann Applanation Tonometry Measurements in Non-pathologic High Myopia. Front Med (Lausanne). 2022 Mar 3;9:819715. doi: 10.3389/fmed.2022.819715. PMID: 35308502; PMCID: PMC8927768.
Kida T, Liu JH, Weinreb RN. Effect of 24-hour corneal biomechanical changes on intraocular pressure measurement. Invest Ophthalmol Vis Sci. 2006 Oct;47(10):4422-6. doi: 10.1167/iovs.06-0507. PMID: 17003435.
Barberán-Bernardos L, Ariza-Gracia MÁ, Piñero DP. Corneal and intraocular pressure changes associated to the circadian rhythms: a narrative review. Int J Ophthalmol. 2024 Oct 18;17(10):1921-1928. doi: 10.18240/ijo.2024.10.20. PMID: 39430020; PMCID: PMC11422371.
Zhu D, Wang L, Qu Z, Wang P, Yuan Y, Yang L, Yao X, Zheng X, Lian H, Wang C, Wang J, Ye Y, Elsheikh A, Bao F, Li J. Diurnal variations in corneal biomechanics in healthy young adults. BMC Ophthalmol. 2025 Feb 26;25(1):90. doi: 10.1186/s12886-025-03913-3. PMID: 40000951; PMCID: PMC11863582.
Nam SM, Lee HK, Kim EK, Seo KY. Comparison of corneal thickness after the instillation of topical anesthetics: proparacaine versus oxybuprocaine. Cornea. 2006 Jan;25(1):51-4. doi: 10.1097/01.ico.0000179929.97651.59. PMID: 16331042.
Lam AK, Chen D. Effect of proparacaine on central corneal thickness values: an evaluation using noncontact specular microscopy and pentacam. Cornea. 2007 Jan;26(1):55-8. doi: 10.1097/01.ico.0000240082.08416.22. PMID: 17198014.
Montero JA, Ruiz-Moreno JM, Fernandez-Munoz M, Rodriguez-Palacios MI. Effect of topical anesthetics on intraocular pressure and pachymetry. Eur J Ophthalmol. 2008 Sep-Oct;18(5):748-50. doi: 10.1177/112067210801800514. PMID: 18850553.
Sibia AS, Banoub RG, Eaddy I, Cheng A, Kubal A, Gupta S, Chalam KV. Immediate Effects of Goldmann Applanation Tonometry on Central Corneal Thickness Measurements Using Contact and Non-contact Pachymetry Methods. Cureus. 2025 Jan 3;17(1):e76852. doi: 10.7759/cureus.76852. PMID: 39897326; PMCID: PMC11787795.
Brandt JD, Gordon MO, Gao F, Beiser JA, Miller JP, Kass MA; Ocular Hypertension Treatment Study Group. Adjusting intraocular pressure for central corneal thickness does not improve prediction models for primary open-angle glaucoma. Ophthalmology. 2012 Mar;119(3):437-42. doi: 10.1016/j.ophtha.2011.03.018. Epub 2011 Jun 25. PMID: 21705084; PMCID: PMC3184359.
Dueker DK, Singh K, Lin SC, Fechtner RD, Minckler DS, Samples JR, Schuman JS. Corneal thickness measurement in the management of primary open-angle glaucoma: a report by the American Academy of Ophthalmology. Ophthalmology. 2007 Sep;114(9):1779-87. doi: 10.1016/j.ophtha.2007.04.068. PMID: 17822980.
- Abstract Viewed: 0 times